4 Circuit Contactor – 12VDC, 24Amp – For RCS4

4 Circuit Contactor – 12VDC, 24Amp – For RCS4

$139.95

4 Circuit Contactor – 12VDC, 24Amp For Remote Cutoff Switch

The Contactor – 4 Circuit 24 Amp, 12VDC allows our RCS4 Remote Cut Off Switch to control up to 4 branch circuits.  Additional contactors can be added to control additional circuits with the same Remote Cutoff Switch.

119 in stock

SKU: SLT-1340 Category: Brand:

Description

Contactor – 4 Circuit 12VDC, 24Amp For RCS4

Features:

  • High Quality ABB Contactor (Noiseless – Hum free)
  • Allows for multiple circuit control with 1 Remote Control Cut Off Switch
  • Up to 4 Branch circuits per contactor
  • For use only with the RCS4 Remote Control Cut Off Switch
  • Mounts on Standard DIN rail – not included

Includes:

  • 24 Amp Contactor: Qty=1

Contactor – 4 Circuit Recommended Circuit Configuration:

  • Four – 15 Amp circuits (Resistive Load Only)
  • Four – 20 Amp circuits (Resistive Load Only)
  • Any combination of four 15 and 20 amp circuits (Resistive Load Only)
  • Consult with your local electrician for proper application

Contactor Technical Details:

  • Normally Closed
  • 4 Pole – 4 individual contactors allowing for control of up to 4 branch circuits
  • 12 VDC coil voltage – used as the trigger
  • Rated 24 amps per contactor – Resistive Current Load (Incandescent Lights, electric heater)
  • Rated for 9 amps per contactor – Reactive Current Load (Motors)

Note:

Inductive loads use magnetic fields (i.e., wire wound coil), as in a furnace, air conditioning unit, or blender. The general rule is, if it moves, it is probably an inductive load, which pulls a large amount of current (inrush current) when it is first energized. But after a few cycles or seconds, the current settles down to a steady state. This steady state is typically the wattage rating you see on the product label. The peak wattage, which occurs with the inrush current, is normally found in the owner’s manual.

Resistive loads convert current into other forms of energy, such as heat. Hair dryers and heaters typically create resistive loads, characterized by not having large inrush currents. The wattage ratings of resistive loads can be taken at face value and are exactly as indicated on their labels.

For any questions, feel free to contact the SLT and Safe and Sound EMF support team at support@safelivingtechnologies.com

You may also like..

Professional EMF Meter safe-and-sound-em3-emf-meter

Safe and Sound EM3 EMF Meter

Safe and Sound EM3 – 3D Magnetic Field, 1D Electric Field, Body Voltage Meter

The meter is built to measure lower frequency electric and magnetic fields; combined into one unit.

Developed and Built North America

Read More »
Safe and Sound Pro II SLT Top Pick

Safe and Sound Pro II RF Meter

5G Ready! – Low And Mid Bands – Third Party Tested

The Safe and Sound Pro II RF Meter is a professional RF meter that is designed to measure ambient radio frequency / microwave signals, and has a built in antenna.

Read More »